The MSA 11KVA Three Phase Generator delivers reliable three phase power in a compact, silenced enclosure. Producing 8.8KW across 240/415V, it is well suited for small construction sites, workshops, and light commercial applications where three phase machinery needs to be powered. The quiet canopy design allows it to operate in noise-sensitive environments without disruption.
Sharing the same compact 1416 x 725 x 1110mm chassis as the 9KVA model, this generator is easy to transport and position on site. The 60L fuel tank provides solid runtime for daily operations, and ATS compatibility ensures seamless integration as a backup power source. Its combination of three phase output, low noise, and portability makes it an excellent choice for contractors and small businesses.
Inc. GST | Free shipping Australia-wide
Voltage
240/415 V
Fuel Tank
60 L
Output KW
8.8 KW
Dimensions
1416*725*1110
Versatile 11KVA three phase silent diesel generator. Suited for small construction sites and commercial use. 8.8KW output in a compact, portable frame.
| Current | 15 AMPS |
|---|---|
| Dimensions (L*W*H) | 1416*725*1110 |
| Frequency | 50 HZ |
| Fuel Tank | 60 L |
| Output KVA | 11 KVA |
| Output KW | 8.8 KW |
| Phase | 3 |
| Power Factor | 0.8 |
| Serial NO | 202512072 |
| Speed | 1500 RPM |
| Voltage | 240/415 V |
| Weight | 604 KG |
Regular maintenance is essential to ensure reliable performance and extend the life of your diesel generator. Follow these key care guidelines:
Oil and Filter Changes: Check engine oil levels regularly using the dipstick when the generator is off and the oil has settled. Change the engine oil and oil filter every 250 to 500 hours of operation or as recommended by the manufacturer.
Coolant System: Inspect coolant levels after the engine has been shut down and cooled. Top up with the correct coolant mixture as needed. Check hoses, connections, and the radiator for leaks or blockages.
Fuel System: Use clean, quality diesel fuel. Drain water from fuel separators weekly. Replace fuel filters at recommended intervals to prevent clogging from dirt, water, or sediment. If the generator is not used frequently, use fuel stabiliser to prevent degradation.
Air Filter: Inspect and clean or replace the air filter regularly to ensure efficient combustion and prevent engine damage.
Battery: Check the battery voltage and terminal connections monthly. Clean terminals to prevent corrosion and ensure tight cable connections. Batteries may need replacement every 2 to 3 years.
General Inspections: Clean the exterior of the generator regularly to prevent dirt and debris from entering filters and vents. Inspect for oil, fuel, or coolant leaks around hoses, gaskets, and connections. Check all mounting hardware and electrical connections for tightness.
Exercising the Generator: If not in regular use, run the generator under load for at least 30 to 60 minutes every month to prevent fuel degradation, carbon buildup, and wet stacking.
Professional Service: Schedule annual professional servicing including load bank testing, compression checks, valve adjustments, and full electrical system inspection.